22 _Disassembly and Reassembly
No. Part name Description Figure
08 BUBBLE
PUMP AND
DRAIN PUMP
6. Release all band rings
and remove the hoses
from the hose drain.
7. Disconnect the terminal
of wire.
8. Remove the screws
holding the Drain Pump.
then separate it.
★
Check points for troubleshooting
1. After separate the drain lter. please check if any alien sub-
stances are inside the pump (such as coins, buttons .., etc.)
→ If found, please clean up.
2. Check whether wire connection correct, if not correct, please
reconnect and ensure the correct.
3. When water leak happens, please check the assembly status of
the clamp hose and the cap drain.
→ Take the relevant countermeasure if necessary.
Turn the lter counterclockwise to remove the remaining water.