7-8
7
SN3308 On-screen Messages
CHAPTER
NOTE 1: BIST is Built In Self Test. This runs continuously
while the SN3308 is operating.
NOTE 2: The internal temperature is continuously
monitored. An overtemp condition will only occur
if the cooling fan failure occurs rst (the fan stops
turning) or the cooling fan lter is clogged or
obstructed. As the temperature rises a warning
will be issued approximately 10 minutes prior to
shutdown as a warning. If shutdown occurs the
SN3308 will shut off the projection lamp and
continue operating, and resume normal operation
as the internal temperature falls.
NOTE 3: The Inverter failure messages will only appear if
a master inverter is installed.
NOTE 4: Gyro Failures will only be annunciated if the
installed Gyro has a valid ag output. If the
"Fluxgate Failed" message appears check the
Gyro circuit breaker which is usually the source
of Fluxgate power.
NOTE 5: All other functions of the SN3308 continue to
operate normally when the map has failed.