1-8. Noise Criterion Curves
Concealed-Duct Type
Single Phase, 50 Hz
Single Phase, 50 Hz
MODEL : SPW-UR184GH56 (A/B)
SPW-UR184SH56B
SPW-U185H
SPW-U185SHT
MODEL : SPW-UR254GH56 (A/B)
SPW-UR254SH56B
SPW-U255H
SPW-U255SHT
SOUND LEVEL :
CONDITION : Under the unit 1.5 m
SOURCE : 220 - 230 - 240 V,
SOUND LEVEL :
STRONG
34 dB(A), NC 22 /
WEAK
27 dB(A), NC 18
STRONG
30 dB(A), NC 23 /
WEAK
25 dB(A), NC 17
CONDITION : Under the unit 1.5 m
SOURCE : 220 - 230 - 240 V,
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
NC-50
NC-40
NC-30
NC-20
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
NC-50
NC-40
NC-30
NC-20
Sound Pressure Level (dB)
(0 dB = 0.0002 µbar)
Frequency at center of sound pressure band (Hz)
Sound Pressure Level (dB)
(0 dB = 0.0002 µbar)
Frequency at center of sound pressure band (Hz)
Strong
Weak
Both 50Hz / 60Hz
MODEL : SPW-UR364GH56 (A/B)
SPW-UR364SH56B
SPW-U365H
SPW-U365SHT SPW-U485SHT
MODEL : SPW-UR484GH56 (A/B)
SPW-UR484SH56B
SPW-U485H
SOUND LEVEL :
CONDITION : Under the unit 1.5 m
SOURCE : 220 - 230 - 240 V, Single Phase, 50Hz Single Phase, 50Hz
SOUND LEVEL :
CONDITION : Under the unit 1.5 m
SOURCE : 220 - 230 - 240 V,
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
NC-50
NC-40
NC-30
NC-20
60
50
40
30
20
10
63 125 250 500 1000 2000 4000 8000
NC-50
NC-40
NC-30
NC-20
Sound Pressure Level (dB)
(0 dB = 0.0002 µbar)
Sound Pressure Level (dB)
(0 dB = 0.0002 µbar)
Frequency at center of sound pressure band (Hz) Frequency at center of sound pressure band (Hz)
STRONG
40 dB(A), NC 33 /
WEAK
33 dB(A), NC 25
STRONG
38 dB(A), NC 30 /
WEAK
31 dB(A), NC 21
1.5 m
Air discharge
(Concealed-Duct Type)
Air intake
Unit
1.5 m directly below unit
Auxiliary Duct
of 2 m length
Auxiliary Duct
of 1 m length
REMARKS: 1. Value obtained in the actual place where the unit is
installed may be slightly higher than the values shown
in this graph because of the conditions of operation,
the structure of the building, the background noise and
other factors.
2. The test results were obtained from an anechoic room.
3. The layout of the testing condition is shown at right.
To evaluate the noise level, the maximum value of the measured sound pressure level is used. Read the value at
each frequency level (on horizontal axis, center of the sound pressure band) from 63 Hz to 8000 Hz, and select the
corresponding maximum value indicated on the vertical axis.
NOTE
Approximate
minimum audible
limit for
continuous noise
Approximate
minimum audible
limit for
continuous noise
Approximate
minimum audible
limit for
continuous noise
Approximate
minimum audible
limit for
continuous noise
SM830161Book.indb98SM830161Book.indb98 2008/06/039:08:072008/06/039:08:07