5-10
5
HIC-C1155GDXH8
(706, 906 Types)
HIC +
Between terminals Resistance
HIC +
HIC +
HIC +
HIC –
HIC –
HIC –
HIC –
U
V
W
U
V
W
Resistance
200 k or more
300 k or more
300 k or more
300 k or more
200 k or more
200 k or more
200 k or more
No
Yes
Replace outdoor unit
control PCB.
(3) [Alarm “E31”]
(communications trouble at unit)
Is “E31”
displayed even after
the power voltage
is reset?
Normal
HIC HIC +UVW
SM830161Book.indb10SM830161Book.indb10 2008/06/039:10:272008/06/039:10:27