89
Appendix
This projector provides a function to control and monitor the projector's operations by using the RS-232C serial port.
Connect a RS-232C serial cross cable to CONTROL PORT
on the projector and serial port on the PC. (See p.19)
Launch a communication software provided with PC and
setup the communication condition as follows:
1
2
3
Baud rate : 9600 / 19200 bps
Parity check : none
Stop bit : 1
Flow control : none
Data bit : 8
Type the command for controlling the projector and then enter
the "Enter" key.
Example
When you want to change the input to INPUT 2, Type 'C' '0' '6'
'Enter'.
Note:
Enter with ASCII 64-byte capital characters and
one-byte characters.
Note:
The default of the baud rate is set to
19200 bps. If an error occurs in the
communication, change the serial port and
the communication speed (baud rate).
Serial Control Interface
Operation
List of Picture in Picture
o : Picture in Picture combinations are enabled.
x : Picture in Picture combinations are disabled.
Note:
When the input signal(s) is/are incompatible, X mark will be displayed on the Main/Sub picture.
Depending on the frequency or signal type of PC/AV input, the display resolution may be lowered or images may not be displayed on
the Main/Sub picture.
<Display resolution is lowered when;>
Inputting PC analog signals: Between 100-140 MHz
<Images are not displayed and X mark appears when;>
Inputting PC analog signals: More than 140MHz
Inputting PC digital signals: More than 100MHz
Inputting AV digital signals: 1080p
<Picture in Picture is disabled when;>
Inputting signal formats: SXGA20, WUXGA 1, WUXGA 2, WSXGA+ 1, WXGA+2, UXGA 1, UXGA 2, UXGA 3, UXGA4, D-1080p