Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
23 Normal Fan5 Max - - 0-255
24 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Eco
33 33 20-100
25 Eco Fan Control Max Temp 38 39 20-100
26 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
72 77 0-255
27 Eco Fan1 Max 125 125 0-255
28 Eco Fan2 Min 68 75 0-255
29 Eco Fan2 Max 80 80 0-255
30 Eco Fan3 Min 77 82 0-255
31 Eco Fan3 Max 135 135 0-255
32 Eco Fan4 Min(LAMP1) - - 0-255
33 Eco Fan4 Max(LAMP1) - - 0-255
34 Eco Fan5 Min(LAMP1) - - 0-255
35 Eco Fan5 Max(LAMP1) - - 0-255
Group
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
60 0-145
1 Fan2 Initial Volt 60 0-145
2 Fan3 Initial Volt 60 0-145
3 Fan4 Initial Volt - 0-255
4 Fan5 Initial Volt Fan Voltage at Power Off (0.1V) - 0-255
5 Fan6-8 Initial Duty - 0-255
6 Fan8 Initial Volt - 0-255
8 Cooling Time L1
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
3 1-15
9 Cooling Time L2
Cooling Time stting at Fan Mode L2 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
4 1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x
30 sec)
3 1-15
11
OnStart Cooling Start Thresh-
old
60 0-100
12 After shutdown cooling Cooling after shutdown (0: No, 1: Yes) 1 0-1
Group
256
Fan Lamp Voltage Down Setting
0 Lamp Voltage
Current Lamp Voltage (0.1V)(Read
only)
- 0-255
1 Lamp Vol Threshold
Threshold to judge Lamp Voltage
Down ( V×10)
30 30-90
2 Fan1 Speed Gain
Additional Fan Speed of Min at Lamp
Voltage Down (unit: 0.1V)
0 0-255
3 Fan2 Speed Gain 300 0-255
4 Fan3 Speed Gain 300 0-255
5 Fan4 Speed Gain 300 0-255
Group
257
Fan Dimmer Setting
0
Dimmer Average Check
Period
Dimmer Avarage measurement Time
(0:10sec, 1:30sec, 2:6sec,
90sec...10:300sec)
1 0-10
1 Dimmer Average Dimmer Avarage Value (Read only) - -
2 Last Voltage Difference - -
3 Voltate Difference Goal
Group
258
Fan IC Temp for Netowrk model
0
Standby Cooling Check
Cycle
Temp A check cycle at Standby 5 0-100
1
Standby Cooling Start
Threshold
Cooling start threshold temp A 46 0-100
2 Standby Cooling Enable Cooling in standby Enable 1 0-1
Group
259
Fan Press Setting
0 Press Ssource Range Low - 0-1023
1 Press Ssource Range High - 0-1023
2
Press Fan Add Range
High(Lamp In)
- 0-5000
3
Press Fan Add Range
Low(Lamp In)
- 0-5000
4
Press Fan Add Range
High(No Lamp In)
- 0-5000
5
Press Fan Add Range Low
(No Lamp In)
- 05000