-47-
Electrical Adjustments
Group/
Item
Item Name Function Initial Range Note
Group
260
Auto Calibration (Commn) * Auto Calibration
0 Execute Calibration 0 0 - 1
Executes Auto-Calibration when
changiing the Value (PC White
100%)
1 Loop Count
Maximum Execution Times (OFFSET-
>GAIN)
8 1 - 30
2 Auto Status
Result of Auto-Calibration (Last
Memory)
0 0 / 1 / 9
0: OK, 1: Adjusting,9: Error *
ReadOnly
3 AutoWait Wait Value for each setting 3 1 - 20
4 CHECK -Tolelance Torelance of OFFSET 4 1 - 255
5 Time out wait Time out waiting time(sec) 20 1-255
Group
261
Auto Calibration (RGB)
0 OFFSET AREA H START
Black Level Acquiring Area H-Start
Position
975 0 - 1000
1 OFFSET AREA V START
Black Level Acquiring Area V-Start
Position
500 0 - 1000
2 GAIN AREA H START
White Level Acquiring Area H-Start
Position
25 0 - 1000
3 GAIN AREA V START
White Level Acquiring Area V-Start
Position
500 0 - 1000
4 Image AREA H WIDTH Black/White Level Acquiring Area 13 0 - 4095
5 Image AREA V HIGHT
Black/White Level Acquiring Area
Height
9 0 - 4095
6 OFFSET target Target Value of Black Level Adj. 20 0 - 1023
7 OFFSET torelance Torelance of Black Level Adj. 1 1 - 1023
8 GAIN target Target Value of White Level Adj. 955 0 - 1023
9 GAIN torelance Torelance of White Level Adj. 1 1 -1023
10 Image Level tolerance 8 1-255
Group
262
Auto Calibration (CVBS/SVIDEO)
0 Y Image Area Start X Y Acquiring Area H-Start Position 20 0 - 1000
1 Y Image Area Start Y Y Acquiring Area V-Start Position 200 0 - 1000
6 Image Area H Width Image Level Acquiring Area 8 0 - 4095
7 Image Area V Hight Image Level Acquiring Area Height 9 0 - 4095
8 Y Target Level Target Value of Y Level Adj. 835 0 - 1023
11 Gain Tolerance Torelance of Level Adj. 1 1 - 255
12 Delta Gain Deviation Width of Gain Value 2 1 - 255
Group
264
Auto Calibration (YCbCr)
0 Y-OFFSET AREA H START
Y - Offset Acquiring Area H-Start
Position
925 0 - 1000
1 Y-OFFSET AREA V START
Y - Offset Acquiring Area V-Start
Position
500 0 - 1000
2
CB - OFFSET AREA H
START
CB - Offset Acquiring Area H-Start
Position
925 0 - 1000 If not used: use Y's value
3 CB - OFFSET AREA V START
CB - Offset Acquiring Area V-Start
Position
500 0 - 1000 If not used: use Y's value
4
CR - OFFSET AREA H
START
CR - Offset Acquiring Area H-Start
Position
925 0 - 1000 If not used: use Y's value
5 CR - OFFSET AREA V START
CR - Offset Acquiring Area V-Start
Position
500 0 - 1000 If not used: use Y's value
6 Y - GAIN AREA H START Y 50 0 - 1000
7 Y - GAIN AREA V START 500 0 - 1000
8 CB - GAIN AREA H START 800 0 - 1000
9 CB - GAIN AREA V START 500 0 - 1000
10 CR - GAIN AREA H START 700 0 - 1000
11 CR - GAIN AREA V START 500 0 - 1000
12 Image AREA H WIDTH YCBCR Level Acquiring Area 13 0 - 4095
13 Image AREA V HIGHT YCBCR Level Acquiring Area Height 9 0 - 4095
14 Y - OFFSET TARTGET 4 0 - 1023
15 CB OFFSET TARGET 512 0 - 1023
16 CR OFFSET TARGET 512 0 - 1023
17 Y - GAIN TARGET 810 0 - 1023
18 CB - GAIN TARGET 894 0 - 1023
19 CR - GAIN TARGET 894 0 - 1023
20 OFFSET torelance Torelance of OFFSET Adj. 1 1 - 255