-13-
1. Remove 4 screws A and remove the Projection lens.
2. Remove 4 screws B and remove the Holder lens unit.
Note :
Each polarizer unit uses different charac-
teristic polarization glasses. Mark the
Polarizer units as they are removed from
the optical unit so that they may be
reassembled in the same location from
which they were removed.
1. Remove 2 screws A and remove the Integrator lens in
unit.
2. Remove 3 screws B and remove the Integrator lens out
& PBS unit.
3. Remove 2 screws C and remove the Condenser lens
unit.
4. Remove 2 screws D and remove the Relay lens unit.
5. Remove 6 screws E and remove the 3 Polarizer units.
2.
Integrator lens in unit, Integrator
lens out & PBS unit, Condenser
lens unit, Relay lens unit and Polarizer
units removal.
1.
Projection lens and Holder lens
unit removal.
Optical unit disassemblies
Projection lens
Holder lens unit.
B
B
B
B
A
A
A
A
Integrator
lens in unit
Relay lens unit
Polarizer
unit Blue
Integrator
lens out
& PBS unit
Condenser
lens unit
A
A
B
B
B
C
C
D
D
E
E
E
E
E
E
Polarizer
unit Red
Polarizer
unit Green
Optical unit