- 21 -
B
B
C
C
C
Panel
Holder-B
CG Mother Board
D
Grounding Lead
Grounding Lead
A
A
Lamp net Board
Holder-A
Washer
Washer
D
Fig.4-3
4
-3
Terminal Slot units disassemblies.
1. Remove 2 screws-A and remove the Lamp net Board.
2. Remove 2 screws-B and remove the Holder-B.
3. Remove 3 screws-C, remove the Holder-A and remove the CG Mother Board.
4. Remove 2 screws-D, remove 2 washers and remove Grounding Lead from the CG Mother Board.
(See Fig.4-3)
Mechanical Disassemblies
C
C
C
C
A
A
A
A
A
B
Terminal Board
units 1-4
A
A
A
D
4-2
Terminal Board units and RS232C Board removal.
Fig.4-2
1. Remove 8 screws-A and remove the Terminal Board units 1-4.
2. Remove screw-B.
3. Remove 4 screws-C and remove the RS232C Board.
4. Remove screw-D, remove washer and remove Grounding Lead from the RS232C Board.
(See Fig.4-2)
Washer
Grounding
lead
RS232C Board