of a wind.
5-8
PFC 1-2 Unit and Sub Power Unit removal.
PFC 1-2 Unit removal.
1. Remove 4 screws-A and remove the PFC 1-2 Unit.
2. Remove 2 screws-B and remove the Holder FAN.
3. Remove the Fan (FN913).
4. Remove 4 screws-C and remove the PFC 1-2 Board.
(See Fig.5-8, 5-8a)
Sub Power Unit removal.
5. Remove 4 screws-D and remove the Sub Power Unit.
6. Remove 6 screws-E and remove the Sub Power Board.
(See Fig.5-8, 5-8b)
Note;
Mark the Fans as they are removed from the holder so that they may be reassembled in the same location from
which they were removed. Be careful of the attachment direction of Fan.
See arrow mark in a figure.
PWB boards may be reassembled in the same location and direction from which they were removed. Be careful of
the attached direction of PWB boards.
Fig.5-8
Fig.5-8a
Fig.5-8b
Mechanical Disassemblies