-104-
Electrical Adjustment
GROUP NO. ITEM FUNCTION RANGE INITIAL VALUE NOTE
13 Alpha Color 0 ~ 1023
120/120/120/120/120/120
/120/120/120/120/120
14 Alpha Tint 0 ~ 1023
10/10/10/10/10/10
/10/10/10/10/10
15 Alpha White Balance -Red 0 ~ 500
40/40/40/40/40/40
/40/40/40/40/40
16 Alpha White Balance -Green 0 ~ 500
40/40/40/40/40/40
/40/40/40/40/40
17 Alpha White Balance -Blue 0 ~ 500
40/40/40/40/40/40
/40/40/40/40/40
18 Alpha Black Balance -Red 0 ~ 500
20/20 /20/20/20/20
/20/20/20/20/20
19 Alpha Black Balance -Green 0 ~ 500
20/20 /20/20/20/20
/20/20/20/20/20
20 Alpha Black Balance -Blue 0 ~ 500
20/20 /20/20/20/20
/20/20/20/20/20
660 Auto Calibration (Common)
0 Execute Calibration Execute auto calibration when the data is set to 1. 0 ~ 1 0 * Gain Adjustment
1 Loop Count 1 ~ 30 10
2 Auto Status Read Only 0 / 1 / 9 0
3 Auto Wait 1 ~ 20 1
4 CHECK - Tolerance 1 ~ 255 8
661 Auto Calibration (RGB)
0 OFFSET AREA H START Black Level H (Unused) 0 ~ 1000 975
1 OFFSET AREA V START Black Level V (Unused) 0 ~ 1000 500
2 GAIN AREA H START White Level H 0 ~ 1000 25
3 GAIN AREA V START White Level V 0 ~ 1000 500
4 ImageAREA H WIDTH Black / White Level H 0 ~ 4095 13
5 ImageAREA V HIGHT Black / White Level V 0 ~ 4095 9
6 OFFSET target Black Level (Unused) 0 ~ 1023 12
7 OFFSET torelance Black Level (Unused) 0 ~ 1023 4
8 GAIN target White Level 0 ~ 1023 941
9 GAIN torelance White Level 0 ~ 1023 4
662 Auto Calibration (CVBS)
0 Y - OFFSET AREA H START Y-Offset Area H Start (Unused) 0 ~ 1000 925
1 Y - OFFSET AREA V START Y-Offset Area V Start (Unused) 0 ~ 1000 500
2 CB - OFFSET AREA H START CB-Offset Area H Start (Unused) 0 ~ 1000 925
3 CB - OFFSET AREA V START CB-Offset Area V Start (Unused) 0 ~ 1000 500
4 CR - OFFSET AREA H START CR-Offset Area H Start (Unused) 0 ~ 1000 925
5 CB - OFFSET AREA V START CB-Offset Area V Start (Unused) 0 ~ 1000 500
6 Y - GAIN AREA H START Y-Gain Area H Start 0 ~ 1000 40
7 Y - GAIN AREA V START Y-Gain Area V Start 0 ~ 1000 495
8 CB - GAIN AREA H START CB-Gain Area H Start 0 ~ 1000 820
9 CB - GAIN AREA V START CB-Gain Area V Start 0 ~ 1000 495
10 CR - GAIN AREA H START CR-Gain Area H Start 0 ~ 1000 690
11 CB - GAIN AREA V START CB-Gain Area V Start 0 ~ 1000 495
12 Image AREA H WIDTH YCBCR Level Area H 0 ~ 4095 13
13 Image AREA V HIGHT YCBCR Level Area V 0 ~ 4095 9
14 Y - OFFSET TARGET Y-Offset target (Unused) 0 ~ 1023 0
15 CB - OFFSET TARGET CB-Offset target (Unused) 0 ~ 1023 512
16 CR - OFFSET TARGET CR-Offset target (Unused) 0 ~ 1023 512
17 Y - GAIN TARGET Y-Gaint target 0 ~ 1023 870
18 CB - GAIN TARGET CB-Gaint target 0 ~ 1023 947
19 CR - GAIN TARGET CR-Gaint target 0 ~ 1023 947
20 OFFSET tolerance Offset tolerance 0 ~ 1023 1
21 GAIN tolerance Offset tolerance 0 ~ 1023 1
664 Auto Calibration (YCbCr)
0 Y - OFFSET AREA H START Y-Offset Area H Start (Unused) 0 ~ 1000 925
1 Y - OFFSET AREA V START Y-Offset Area V Start (Unused) 0 ~ 1000 500
2 CB - OFFSET AREA H START CB-Offset Area H Start (Unused) 0 ~ 1000 925
3 CB - OFFSET AREA V START CB-Offset Area V Start (Unused) 0 ~ 1000 500
4 CR - OFFSET AREA H START CR-Offset Area H Start (Unused) 0 ~ 1000 925
5 CB - OFFSET AREA V START CB-Offset Area V Start (Unused) 0 ~ 1000 500
6 Y - GAIN AREA H START Y-Gain Area H Start 0 ~ 1000 40
7 Y - GAIN AREA V START Y-Gain Area V Start 0 ~ 1000 495
8 CB - GAIN AREA H START CB-Gain Area H Start 0 ~ 1000 820
9 CB - GAIN AREA V START CB-Gain Area V Start 0 ~ 1000 495
10 CR - GAIN AREA H START CR-Gain Area H Start 0 ~ 1000 690
11 CR - GAIN AREA V START CB-Gain Area V Start 0 ~ 1000 495
12 Image AREA H WIDTH YCBCR Level Area H 0 ~ 4095 13
13 Image AREA V HIGHT YCBCR Level Area V 0 ~ 4095 9
14 Y - OFFSET TARGET Y-Offset target (Unused) 0 ~ 1023 0
15 CB - OFFSET TARGET CB-Offset target (Unused) 0 ~ 1023 512
16 CR - OFFSET TARGET CR-Offset target (Unused) 0 ~ 1023 512
17 Y - GAIN TARGET Y-Gaint target 0 ~ 1023 870
18 CB - GAIN TARGET CB-Gaint target 0 ~ 1023 947
19 CR - GAIN TARGET CR-Gaint target 0 ~ 1023 947
20 OFFSET tolerance Offset tolerance 0 ~ 1023 1