-136-
Troubleshooting
Error
Error
Code
Error Infomation
(See Powe Failure Detection Tree)
Error
Code
Error Infomation
(See Powe Failure Detection Tree)
Normal 0 -
Power Failure
1000 MAIN, 5V 1021 MAIN, K8G
1001 MAIN, -5V 1022 MAIN, PFC3
1002 MAIN, 3V 1023 MAIN, PFC4
1003 MAIN, S9V 1024 MAIN, DCFAN1
1004 MAIN, S16V 1025 MAIN, DCFAN2
1005 MAIN, 16VM 1026 ERR, PRESSURE
1006 MAIN, 12VA 1027 ERR, FIL_DET
1007 MAIN, 1.8VAD 1028 ERR, FIL_MTR
1008 MAIN, 3.3VAD 1029 ERR, SHUT_MTR
1009 MAIN, 1.2VFST 1030 ERR, EXT_FAN
1010 MAIN, PLLFST 1031 SUBPOW, 12VF3
1011 MAIN, 1.2VPIC 1032 FAN, NET_FAN
1012 MAIN, PLLPIC
1033 SUBPOW, 12VF2
1013 MAIN, 1.8VGAM 1034 FAN, IN_FAN
1014 MAIN, 2.5VGAM 1035 SUBPOW, 12VF1
1015 MAIN, 3.3VGAM 1036 SUBPOW, 16VA
1016 MAIN, 15.5VGAM 1037 ERR, IIC_DATA
1017 MAIN, K8E 1038 SLOT1
1018 MAIN, THERMO 1039 SLOT2
1019 MAIN, FN910 1040 SLOT3
1020 MAIN, FN911
1041 SLOT4
Temperature Error
2000
Temperature Error detected on the Sensor (IC8811) (Arround the Intake Duct)
2001
Error of the detection (IC8811 communication error)
2100 Error of the detection (IC2541 communication error)
2200
Temperature Error detected on the Sensor (IC8811) and Thermister (TH901)
Lamp Error
3000 Lamp1 fails on
3001 Lamp1 goes out
3002
Communication Error on Lamp1
3100 Lamp2 fails on
3101 Lamp2 goes out
3102 Communication Error on Lamp2
System Error
4000 FPGA IO, NIOS Config Error
4001 FPGA MOTHER Config Error
4002
FPGA SW, FINE Config Error
4003 PW DPORT OUT Error
Error History Log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and se-
lect Group No. "91" and Item No. "0" to "49". The error code
is displayed on the Data column. The description of the error
code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
91 0
1
2
3
:
:
49
✻
<- Latest Error
✻
✻
✻
:
:
✻
How to reset the Error History Log
1. Enter the Service Mode, and select Group No. "91" and Item No. "50".
2 The history log will be reset when the Data Value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Operation".