Optical Parts Disassembly
2 Polarized glass/Optical filter ass'y removal
Remove 2 screws-A (M3x6) on each stopper and take the polarized glasses upward
off.
A
A
A
Polarized glass/Optical filter ass'y
(M2x2)
(M2x2)
(M2x2)
(M2x2)
(M2x2)
Pre-polarized glass
Polarized glass
Optical filter(HCP)
TH901(Thermal sensor)
Only the B-Polarized glass/Optical
filter ass'y provides these parts.
Marking
Prism side
Holder