Electrical Adjustments
Group/
Item
Item Name Function Initial Range
Note
15
Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
5 0-100
16
Temp B Warning Offset
(Temp)
5 0-100
17
Temp C Warning Offset
(Temp)
5 0-100
18
Temp B-A Warning Offset
(Temp)
0 0-100
19
Temp C-A Warning Offset
(Temp)
0 0-100
20
Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
3 0-5
21
Temp B Warning Offset
(Time)
3 0-5
22
Temp C Warning Offset
(Time)
3 0-5
23
Temp B-A Warning Offset
(Time)
3 0-5
24
Temp C-A Warning Offset
(Time)
3 0-5
Group
254
Fan Control Range Setting (Temp./Voltage)
Normal Ceiling HiLand-Normal HiLand-Ceiling
0 High Fan Control Min Temp 33 35 33(On1),34(On2) 35(On1),36(On2) -
1 High Fan Control Max Temp 40 46 40(On1),42(On2) 43(On1),44(On2) -
2 High Fan1 Min 68 68 83(On1),93(On2) 85(On1),95(On2) -
3 High Fan1 Max 135 135 135 135 -
4 High Fan2 Min 75 85 88(On1),100(On2) 98(On1),110(On2) -
5 High Fan2 Max 100 105
113(On1),125(On2)
118(On1),130(On2) -
6 High Fan3 Min 80 85 85(On1),100(On2) 90(On1),105(On2) -
7 High Fan3 Max 135 135 135 135 -
10 Normal Fan Control Min Temp
Temp Sensor Control Start/End Tem.p
at Normal
33 35 33(On1),34(On2) 35 20-100
11
Normal Fan Control Max
Temp
40 45 40(On1), 41(On2) 42(On1),43(On2) 20-100
12 Normal Fan1 Min
Fan voltage value at Normal (unit: 0.1V)
58 58 80(On1),90(On2) 85(On1),95(On2) 0-255
13 Normal Fan1 Max 135 135 135 135 0-255
14 Normal Fan2 Min 73 85 88(On1),100(On2) 101(On1),113(On2) 0-255
15 Normal Fan2 Max 96 101
112(On1), 124(On2)
117(On1),129(On2)
0-255
16 Normal Fan3 Min 75 80 85(On1),100(On2) 90(On1),105(On2) 0-255
17 Normal Fan3 Max 135 135 135 135 0-255
20 Eco Fan Control Min Temp
Temp Sensor Control Start/End Tem.p
at Eco
34 35 32(On1),33(On2) 34 20-100
21 Eco Fan Control Max Temp 40 41 40 41(On1), 42(On2) 20-100
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
50 50 60(On1),70(On2) 65(On1),75(On2) 0-255
23 Eco Fan1 Max 120 120 125 125 0-255
24 Eco Fan2 Min 45 45 48(On1),60(On2) 48(On1),60(On2) 0-255
25 Eco Fan2 Max 65 70 68(On1),80(On2) 73(On1),85(On2) 0-255
26 Eco Fan3 Min 55 60 60(On1),75(On2) 65(On1),80(On2) 0-255
27 Eco Fan3 Max 110 110 115 115 0-255
Group
255
Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage(0.1V)
55 0-255
1 Fan2 Initial Volt 55 0-255
2 Fan3 Initial Volt 55 0-255
4 Fan1 Cooling Speed
Fan Voltage at Power Off (0.1V)
135 0-255
5 Fan2 Cooling Speed 100 0-255
6 Fan3 Cooling Speed 135 0-255
8 Cooling Time L1
Cooling Time setting at Fan Mode L1
(x 30 sec) 1: 30, 3: 90, 15: 450 sec.
2 1-15
9 Cooling Time L2
Cooling Time setting at Fan Mode L2
(x 30 sec)
1: 30, 3: 90, 15: 450 sec.
3 1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x
30 sec)
3 1-15
11
OnStart Cooling Start Thresh-
old
38 0-100
12 After shutdown cooling Cooling after shutdown (0: No, 1: Yes) 1 0-1
Group
256
Fan/Lamp Voltage Dimmer Setting
2 Fan 1 Speed Gain 10 0-255
3 Fan 2 Speed Gain 10 0-255