-68-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
8 Cooling Time Cooling Time Setting (x30 sec.) 1: 30 3: 90 15: 450 1-15 3
10 Temp Error Cooling Time
Cooling Time Setting When the Temp Error occurs (x30 sec.)
1: 30 3: 90 15: 450
1-15 3
11 OnStart Cooling Start Threshold 0-100 60
12 After shutdown cooling Cooling Operation after Shut Down (0: No, 1: Yes) 0-1 1
256 Fan Lamp Voltage Down Setting
0 Lamp Voltage Current Lamp Voltage (0.1V) (Read only) 0-255 ---
1 Lamp Vol Threshold Threshold Voltage (0.1V) 30-90 30
2 Fan1 Speed Gain Fan Speed Ad Gain (0.1V) 0-1500 0
257 Fan Setting at Dimmer
0 Dimmer Average Check Period
Dimmer Average Check Period (sec.)
0: 10, 1: 30, 2: 60, 3: 90……10:300
0-10 1
258 Fan Control Range Setting (for Lamp2)
0 High Fan4 Min (LAMP2)
Fan Spinning (Min/Max) (rpm)
0000 - 9990 5200 3256 5200 5200
1 High Fan4 Max (LAMP2) 0000 - 9990 5200 3256 5600 5600
2 High Fan5 Min (LAMP2) 0000 - 9990 3256 5200 3256 3256
3 High Fan5 Max (LAMP2) 0000 - 9990 3256 5200 3656 3656
4 Normal Fan4 Min (LAMP2) 0000 - 9990 4424 2880 4424 4424
5 Normal Fan4 Max (LAMP2) 0000 - 9990 4424 2880 4824 4824
6 Normal Fan5 Min (LAMP2) 0000 - 9990 2880 4424 2880 2880
7 Normal Fan5 Max (LAMP2) 0000 - 9990 2880 4424 3280 3280
8 Eco Fan4 Min (LAMP2) 0000 - 9990 3640 2504 3640 3640
9 Eco Fan4 Max (LAMP2) 0000 - 9990 3640 2504 4040 4040
10 Eco Fan5 Min (LAMP2) 0000 - 9990 2504 3640 2504 2504
11 Eco Fan5 Max (LAMP2) 0000 - 9990 2504 3640 2904 2904
259 Fan Air Pressure Setting
0 Press Source Range Low Pressure Sensor Control Range (AD) 0-1024 645
1 Press Source Range High 0-1024 825
2
Press Fan Add Range High(lamp
in)
Add Spinning (Lamp Intake fan)
0 - 5000 1082
3
Press Fan Add Range Low(lamp
in)
0 - 5000 2704
4
Press Fan Add Range High(no
lamp in)
Add Spinning (without Lamp Intake fan)
0 - 5000 720
5
Press Fan Add Range Low(no
lamp in)
0 - 5000 1432
260 Auto Calibration (Common) * Auto calibration
0 Execute Calibration
Execute Calibration when the Value is changed to 1. (For PC
White 100%)
0 - 1 0
1 Loop Count Max Times of Calibration 1 - 30 8
2 Auto Status
Calibration Log (Read only)
0: Calibration End Correctly 1: On Adjusting 9: Calibration
Error
0 / 1 / 9 0
3 AutoWait Waiting time 1 - 20 3
4 CHECK - Tolerance Tolerance of Offset 1 - 255 4
5 Time out wait Wait Time until Time out [sec.] 1 - 255 20
261 Auto Calibration (RGB) PW392-AFE MDL <10bits>
0 OFFSET AREA H START Black Level Acq. Area H Start 0 - 1000 975
1 OFFSET AREA V START Black Level Acq. Area V Start 0 - 1000 500
2 GAIN AREA H START White Level Acq. Area H Start 0 - 1000 25
3 GAIN AREA V START White Level Acq. Area V Start 0 - 1000 500
4 Image AREA H WIDTH Black/White Level Area Width 0 - 4095 13
5 Image AREA V HEIGHT Black/White Level Area Height 0 - 4095 9
6 OFFSET Target Black Level Adj target 0 - 1023 20
7 OFFSET Tolerance Black Level Adj telerance 1 - 1023 1
8 GAIN Target White Level Adj target 0 - 1023 955
9 GAIN Tolerance White Level Adj telerance 1 - 1023 1
10 Image Level Tolerance Acq. Image Level Adj Tolerance 1 - 255 8
262 Auto Calibration (CVBS/SVIDEO) PW392-AFE MDL <10bits>
0 Y Image Area Start X Y Image Area H Start 0 - 1000 20
1 Y Image Area Start Y Y Image Area V Start 0 - 1000 200
6 Image Area H WIDTH Image Level Acq. Width 0 - 4095 8
7 Image Area V HEIGHT Image Level Acq. Height 0 - 4095 9
8 Y Target Level Y Level Adj target 0 - 1023 875
11 Gain Tolerance Level Adj Tolerance 1 - 255 1