EasyManua.ls Logo

Sanyo PLC-XTC50L - Error History Log

Sanyo PLC-XTC50L
172 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
-88-
Chassis Description
Error Error Code
Error Infomation
(See Powe Failure Detection System)
Error Code
Error Infomation
(See Powe Failure Detection System)
Normal 0 -
Power Failure
1000
FPGA, 1.2V
1017
FAN8, FANLOCK
1001
GAMMA, 1V
1018
FILTER, DET
1002
KS, 1.8V
1019
MOTOR, TIMEOUT
1003
KS, 2.5V
1020
PRESS, ERROR
1004
MAIN/AV, 3.3V
1021
FPGASW, CONFIG
1005
MAIN/AV, 9/5V
1022
SHUTTER, ERROR
1006
M/AU, 15/12/9/5V
1023
MIRROR, ERROR
1007
RELAY, 12V
1008
MAIN/AV, S-5V
1009
PJ_NET, 5/3.3V
1010
FAN1, FANLOCK
1011
FAN2, FANLOCK
1012
FAN3, FANLOCK
1013
FAN4, FANLOCK
1014
FAN5, FANLOCK
1015
FAN6, FANLOCK
1016
FAN7, FANLOCK
Temperature Error
2000 Sensor A detects abnormal temperature. (TH901)
2001 Sensor A fails measurement. (TH901)
2100 Sensor B detects abnormal temperature. (IC8841)
2101 Sensor B fails measurement. (IC8841)
2102 Sensors B-A temperature error.
2200 Sensor C detects abnormal temperature. (IC8871)
2201 Sensor C fails measurement. (IC8871)
2202 Sensors C-A temperature error.
Lamp Error
3000 Lamp1 fails on
3001 Lamp2 fails on
3002 Lamp1 goes out
3003 Lamp2 goes out
3004 Communication Error on Lamp1
3005 Communication Error on Lamp2
System Error 4000
FPGASW, CONFIG
Shutter Error 5000
SHUTTER, ERROR
Filter Error 6000 Filter clogged
Error History Log
This projector provides the error history log function. To
check the logs, you need to enter the service mode and
select Group No. "220" and Item No. "0" to "49". The error
code is displayed on the Data column. The description of
the error code is listed on the table below.
* How to enter the service mode and select the group, item
and data value, see "Service Adjustment Menu Opera-
tion".
Group
No.
Item
No.
Data
(Error Code)
220 0
1
2
3
:
:
49
✻
<- Latest Error
:
:
How to reset the Error History Log
1. Enter the Service Mode, and select Group No. "220" and Item No. "50".
2 The history log will be reset when the Data Value is set to "10". The value automatically returns to "0".
* How to enter the service mode and select the group, item and data value, see "Service Adjustment Menu Operation".

Table of Contents

Other manuals for Sanyo PLC-XTC50L

Related product manuals