-42-
Group/
Item
ITEM NAME FUNCTION INITIAL RANGE NOTE
17 DIMMER_LEVEL_AUTO Current Dimmer Leverl - - * Read only
18 DIMMER_LEVEL_NORMAL Normal Dimmer Level 12 0 - 15
19 DIMMER_LEVEL_ECO Eco Dimmer Level 0 0 - 15
20 Panel life mode Panel life mode 0 0 - 1
21 VOLTAGE_LEVEL Lamp Voltage - Unit: 8bit(Raw Data) * Read only
Group 250 FAN Cntorol
*Fon Control Adjustment
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan Volage.
* Lamp mode is forced Eco
10 0 - 255
1 FAN1 MAX ADJUST (DAC) 225 0 - 255
2 FAN2 MIN ADJUST (DAC)
PLC-XU78 : 36
PLC-XU75 : 10
0 - 255
3 FAN2 MAX ADJUST (DAC) 225 0 - 255
4 Not used
9999
5 Not used
9999
6 Not used
9999
7 Not used
9999
Group 251
Not used
Group 252 Fan Option
0 HI-LAND SWITCH 0: Normal, 1: Hi-Land, 2-4: Hi-Land 1-3 0 0 - 5
1 SAFETY SWITCH For test purpose 0 0 - 6
2 FAN MANUAL SWITCH 0: Auto, 1: Manual 0 0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Maual switch is 1
100 0 - 255
4 FAN2 MANUAL VOLTAGE 100 0 - 255
5 Not used
9999
6 Not used
9999
PLC-XU78
Group 253 Fan Tem Error Setting (Memorized) Normal Ceiling
HiLand-
Normal
HiLand-
Ceiling
0
Not used
9999
1
Not used
9999
2
Not used
9999
3
Not used
9999
4
Not used
9999
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at Normal
(Room)
41 41 34 34 30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at Normal
(Panel)
59 59 56 55 30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at Normal
(Lamp)
67 67 64 63 30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
10 Temp A Warning (Eco) Temp. A to judge the Temp Error at Eco (Room)
42 42 37 35 30-100
11 Temp B Warning (Eco) Temp. B to judge the Temp Error at Eco (Panel)
59 59 56 55 30-100
12 Temp C Warning (Eco) Temp. C to judge the Temp Error at Eco (Lamp)
67 68 62 61 30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100 100 100 100 0-100
15 Temp A Warning Offset (Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at the
below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5 0-100
16 Temp B Warning Offset (Temp)
5 0-100
17 Temp C Warning Offset (Temp)
5 0-100
18 Temp B-A Warning Offset (Temp)
0 0-100
19 Temp C-A Warning Offset (Temp)
0 0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X minute at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
3 0-5
21 Temp B Warning Offset (Time)
3 0-5
22 Temp C Warning Offset (Time)
3 0-5
23 Temp B-A Warning Offset (Time)
3 0-5
24 Temp C-A Warning Offset (Time)
3 0-5
PLC-XU75
Group 253 Fan Tem Error Setting (Memorized) Normal Ceiling
HiLand-
Normal
HiLand-
Ceiling
0
Not used
9999
1
Not used
9999
2
Not used
9999
3
Not used
9999
4
Not used
9999