EasyManua.ls Logo

Sanyo SAP–K181AHA–S - Cooling Capacity

Sanyo SAP–K181AHA–S
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
5-3. Cooling Capacity
240V Single Phase 50Hz
Indoor Unit SAPK181AHA
Outdoor Unit SAPC181AHA
RATING CAPACITY 4.95 kW
AIR FLOW RATE 760
m
3
/h
EVAPORATOR CONDENSER
ENT. TEMP. °C OUTDOOR AMBIENT TEMP. °C
W.B. D.B. 30 35 40 43
TC 4.55 4.34 4.07 3.75
CM 1.91 2.05 2.19 2.36
21 SHC 3.04 2.92 2.79 2.62
15 23 SHC 3.39 3.28 3.14 2.98
25 SHC 3.75 3.63 3.50 3.33
27 SHC 4.10 3.99 3.85 3.69
29 SHC 4.46 4.34 4.07 3.75
31 SHC 4.55 4.34 4.07 3.75
TC 4.89 4.65 4.37 4.02
CM 1.96 2.10 2.25 2.42
21 SHC 2.67 2.56 2.42 2.26
17 23 SHC 3.03 2.91 2.78 2.61
25 SHC 3.38 3.27 3.13 2.97
27 SHC 3.74 3.62 3.49 3.32
29 SHC 4.09 3.98 3.84 3.68
31 SHC 4.45 4.33 4.20 4.02
TC 5.20 # 4.95 4.65 4.28
CM 2.02 2.17 2.32 2.49
21 SHC 2.29 2.18 2.04 1.88
19 23 SHC 2.64 2.53 2.40 2.23
25 SHC 3.00 2.89 2.75 2.59
27 SHC 3.35 3.24 3.11 2.94
29 SHC 3.71 3.59 3.46 3.30
31 SHC 4.06 3.95 3.82 3.65
TC 5.51 5.25 4.93 4.54
CM 2.08 2.23 2.39 2.56
23 SHC 2.25 2.14 2.01 1.85
21 25 SHC 2.61 2.50 2.36 2.20
27 SHC 2.96 2.85 2.72 2.56
29 SHC 3.32 3.20 3.07 2.91
31 SHC 3.67 3.56 3.43 3.27
TC 5.84 5.51 5.16 4.80
CM 2.13 2.29 2.45 2.63
23 25 SHC 2.19 2.06 1.93 1.79
27 SHC 2.54 2.42 2.28 2.15
29 SHC 2.90 2.77 2.64 2.50
31 SHC 3.25 3.13 2.99 2.86
TC : Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.

Table of Contents