9-3-4. Only outdoor fan does not run.
9-3-5. Only compressor does not run.
NO
YES
YES
YES
Measure coil resistance of
starting relay. (SR)
Measure resistance of
compressor motor winding.
Check capacitors.
(Either C or BC)
Either internal protector or
overload relay is working.
(49C or OLR)
YES
Temperature of compressor
is abnormally high.
Refrigerant gas shortage. Charge refrigerant gas (R22).
Rotor may be locked up.
Measure coil resistance of
power relay. (PR)
Fan cannot
be turned.
OK
Check fan rotation.
Turn fan gently once or twice by
hand.
Check fan casing
foreign matter on
inside.
Fan motor burnout
or foreign matter in
bearings.
Remove foreign
matter or repair.
Repair or replace.
Measure resistance of outdoor fan
motor winding.
Check fan motor capacitor.