Loading...
Outdoor Unit SAP-C97GHAX
13
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Controller PCB
Compressor
Type Single Rotary
Compressor model / Nominal output C-1R81H5T / 800W
Compressor oil ... Amount CC SAY-56T …320
Coil resistance (Ambient temp. 25
C) Ohm C - R : 4.27
C - S : 4.56
Safety devices Type External ( OLR )
Overload relay MRA99248-9201
Operating temp. Open
C
155
5
Close
C
69
11
Operating amp.(Ambient temp. 25
C) Trip in 6 to 16 sec. at 17.0A
Run capacitor
Micro F
30.0
VAC
370
Crankcase Heater -
Fan
Type Propeller
Q'ty … Dia. mm 1 … D380
Fan Motor
Type AC Motor
Fan motor model ... Q'ty IB-976-501D … 1
No. of poles 6
Rough Measure RPM (Cool/Heat) 820 / 820
Nominal output W 25
Coil resistance (Ambient temp. 20
C)
Ohm
BRN - WHT :
213.4
10%
RED(PNK) - WHT :
167.7
10%
Safety devices Type Thermal protector
Operating temp. Open
C110
Close
C-
Run capacitor
Micro F
2.0
VAC 440
Heat Exchanger Coil
Coil Aluminum Plate Fin / Copper Tube
Rows 1
Fin pitch mm 1.2
Face area
m
2
0.341
External Finish
Acrylic baked-on enamel finish