EasyManua.ls Logo

Sanyo SAP-K77GHAX - DIMENSIONAL DATA

Sanyo SAP-K77GHAX
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Outdoor Unit SAP-C127GHAX
14
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Controller PCB
Compressor
Type Single Rotary
Compressor model / Nominal output C-R115H5A / 1,110W
Compressor oil ... Amount CC SAY-56T … 520
Coil resistance (Ambient temp. 25
C) Ohm C - R : 1.962
C - S : 5.38
Safety devices Type External (OLR)
Overload relay MRA98619-9200
Operating temp. Open
C 150 +/- 5
Close
C 69 +/- 11
Operating amp.(Ambient temp. 25
C) Trip in 6 to 16 sec. at 22.5A
Run capacitor
Micro F
25.0
VAC 400
Crankcase Heater -
Fan
Type Propeller
Q'ty … Dia. mm 1 … D380
Fan Motor
Type AC Motor
Fan motor model ... Q'ty UE4-Z51D5P R … 1
No. of poles 4
Rough Measure RPM (Cool/Heat) 1,070 / 1,020
Nominal output W 47.6
Coil resistance (Ambient temp. 20
C)
Ohm
(GRY)BRN - WHT : 152.1
RED - WHT : 138.7
Safety devices Type Thermal protector
Operating temp. Open
C
135
±
5
Close
C
86
±
15
Run capacitor
Micro F
2.5
VAC 450
Heat Exchanger Coil
Coil Aluminum Plate Fin / Copper Tube
Rows 1
Fin pitch mm 1.2
Face area
m
2
0.373
External Finish
Acrylic baked-on enamel finish

Table of Contents