Indoor Unit SAPKR224GJH
Outdoor Unit SAPCR224GH
240V Single Phase 50Hz
RATING CAPACITY 6.40 kW
AIR FLOW RATE 980
m
3
/h
EVAPORATOR CONDENSER
ENT. TEMP. °C OUTDOOR AMBIENT TEMP. °C
W.B. D.B. 30 35 40 43
TC 5.89 5.61 5.27 4.85
CM 1.83 1.96 2.36 3.04
21 SHC 4.01 3.87 3.70 3.49
15 23 SHC 4.50 4.36 4.19 3.98
25 SHC 4.99 4.85 4.68 4.47
27 SHC 5.48 5.34 5.17 4.85
29 SHC 5.89 5.61 5.27 4.85
31 SHC 5.89 5.61 5.27 4.85
TC 6.32 6.02 5.66 5.20
CM 1.88 2.02 2.42 3.09
21 SHC 3.51 3.37 3.20 2.99
17 23 SHC 4.00 3.86 3.69 3.48
25 SHC 4.49 4.35 4.18 3.97
27 SHC 4.98 4.84 4.67 4.46
29 SHC 5.47 5.33 5.16 4.95
31 SHC 5.96 5.82 5.65 5.20
TC 6.72 # 6.40 6.02 5.54
CM 1.94 2.08 2.49 3.17
21 SHC 2.98 2.84 2.67 2.47
19 23 SHC 3.47 3.33 3.16 2.96
25 SHC 3.96 3.82 3.65 3.45
27 SHC 4.45 4.31 4.14 3.94
29 SHC 4.94 4.80 4.63 4.43
31 SHC 5.43 5.29 5.12 4.92
TC 7.12 6.78 6.38 5.87
CM 1.99 2.14 2.55 3.23
23 SHC 2.94 2.80 2.63 2.43
21 25 SHC 3.43 3.29 3.12 2.92
27 SHC 3.92 3.78 3.61 3.41
29 SHC 4.41 4.27 4.10 3.90
31 SHC 4.90 4.76 4.59 4.39
TC 7.55 7.12 6.67 6.20
CM 2.04 2.19 2.61 3.29
23 25 SHC 2.86 2.70 2.53 2.36
27 SHC 3.35 3.19 3.02 2.85
29 SHC 3.84 3.68 3.51 3.34
31 SHC 4.33 4.17 4.00 3.83
TC : Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CM : Compressor Input (kW)
Rating conditions (#Mark) are
Outdoor Ambient Temp. 35°C D.B.
Indoor Unit Entering Air Temp. 27°C D.B. / 19°C W.B.