Loading...
8. FUNCTION
8-1. Room Temperature Control
Cooling
Room temperature control is obtained by cycling the compressor ON and OFF under control of the room
temperature sensor in the remote control unit.
The room temperature (and other information) is transmitted every 5 minutes by the remote control unit to the
controller in the indoor unit.
Once the compressor starts, it keeps running for 5 minutes.
Once the compressor stops, it will not start running again for 3 minutes.
Thermo ON : When room temperature rises 1°C above the set temperature T˚C.
Compressor
ON
Thermo. OFF : When the room temperature decreases below the set temperature T°C.
Compressor
OFF
Whenever the compressor is running, the indoor unit always generates negative ions. (ION lamp lights up.).
NOTE
ON OFF ON OFF ON OFFCompressor
ON OFF ON OFF ON OFFOutdoor fan
T+1°C
T °CSet temp.
Thermo.
OFF
Thermo.
OFF
Thermo.
ON
Thermo.
OFF
Thermo.
ON
Thermo.
ON
Thermo.
ON
Room temp.
5 minutes
5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes
Signal from remote control unit