8. FUNCTION
8-1. Room Temperature Control
■
Cooling
●
Room temperature control is obtained by cycling the compressor ON and OFF under control of the room
temperature sensor in the remote control unit.
●
The room temperature (and other information) is transmitted every 5 minutes by the remote control unit to the
controller in the indoor unit.
●
Once the compressor starts, it keeps running for 5 minutes.
●
Once the compressor stops, it will not start running again for 3 minutes.
●
Thermo ON : When room temperature rises 1°C above the set temperature T˚C.
Compressor
➞
ON
●
Thermo. OFF : When the room temperature decreases below the set temperature T°C.
Compressor
➞
OFF
● Whenever the compressor is running, the indoor unit always generates negative ions. (ION lamp lights up.).
ON OFF ON OFF ON OFFCompressor
ON OFF ON OFF ON OFFOutdoor fan
T+1°C
T °CSet temp.
Thermo.
OFF
Thermo.
OFF
Thermo.
ON
Thermo.
OFF
Thermo.
ON
Thermo.
ON
Thermo.
ON
Room temp.
5 minutes
5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes
Signal from remote control unit