Heating
Room temperature control is obtained by cycling the compressor ON and OFF under control of the room
temperature sensor in the remote control unit.
The room temperature (and other information) is transmitted every 5 minutes by the remote control unit to the
controller in the indoor unit.
Once the compressor starts, it keeps running for 5 minutes.
Once the compressor stops, it will not start running again for 5 minutes.
Thermo ON : When room temperature decreases below –1°C below the set temperature T˚C.
Compressor
ON
Thermo. OFF : When the room temperature rises 1°C above the set temperature T°C.
Compressor
OFF
Whenever the compressor is running, the indoor unit always generates negative ions. (ION lamp lights up.).
The temperature described in this page and previous page gives you an example with remote control operation.
In case of a body sensor operation, operation temperature differ somewhat.
NOTE
ON OFF ONCompressor OFF
OFF
ONOutdoor fan
4–way valve
OFF
ON
Thermo.
OFF
Thermo.
ON
Thermo.
OFF
T+1 °C
T °C
T–1 °C
Set temp.
Room temp.
5 minutes 5 minutes 5 minutes 5 minutes 5 minutes 5 minutes