9-3. Some part of air conditioner does not operate.
9-3-1. Only indoor fan does not run.
9-3-2. Only flap motor does not run.
9-3-3. Only outdoor fan does not run.
Fan cannot
be turned.
Check fan rotation.
Turn fan gently once or twice by
hand.
Check fan casing
foreign matter on
inside.
Fan motor winding
burnout or foreign
matter in bearings.
Remove foreign
matter or repair.
Repair or replace.
OK
Check fan motor capacitor.
OK
Check fan motor capacitor.
Check connectors to indoor PCB Ass´y.
Measure resistance of outdoor fan
motor winding.
Check connectors to outdoor fan
motor lead wires.
Measure resistance of flap motor
winding and connector.
Fan cannot
be turned.
Check fan rotation.
Turn fan gently once or twice by
hand.
Check fan casing
foreign matter on
inside.
Fan motor winding
burnout or foreign
matter in bearings.
Remove foreign
matter or repair.
Repair or replace.
Check connectors to PCB Ass´y.
Refer to " 9-4-3. Trouble Diagnosis of Indoor Fan Motor ".