COOLING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 240V Single phase 50Hz
Rating Conditions Running Amps. A 0.37 0.71 8.53 9.6
Power Input kW 0.041 0.161 2.078 2.280
Full Load Conditions Running Amps. A 0.37 0.71 15.61 12.0
Power Input kW 0.041 0.161 3.294 2.730
Rating Conditions : Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 240V Single phase 50Hz
Rating Conditions Running Amps. A 0.37 0.71 8.33 9.40
Power Input kW 0.041 0.161 2.038 2.240
Full Load Conditions Running Amps. A 0.37 0.71 15.71 12.0
Power Input kW 0.041 0.161 3.294 2.730
Rating Conditions : Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°C D.B. / 18°C W.B.
Indoor Unit SAP–KR224GJH
Outdoor Unit SAP–CR224GH