7
Indoor Unit SAPKR224GJH
Outdoor Unit SAPCR224GH
Power Source 220–240V Single phase 50Hz
Voltage rating 220 / 230 / 240 V
Performance Cooling Heating
Capacity kW 6.40 / 6.40 / 6.40 7.20 / 7.20 / 7.20
BTU/h 21,800 / 21,800 / 21,800 24,600 / 24,600 / 24,600
Air circulation (High)
m
3
/h
980 980
Moisture removal (High) Liters/h 3.3
Electrical Rating Cooling Heating
Available voltage range V 198 ~ 264
Running amperes A 10.4 / 10.0 / 9.6 10.3 / 9.8 / 9.4
Power input W 2,275 / 2,275 / 2,280 2,240 / 2,240 / 2,240
Power factor % 99 / 99 / 99 99 / 99 / 99
C.O.P. W/W 2.81 / 2.81 / 2.81 3.21 / 3.21 / 3.21
Compressor locked rotor amperes A 49 49
Features
Controls / Temperature control Microprocessor / I.C. thermister
Control unit Wireless remote controller
Timer ON/OFF 24 hours & Daily program,1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / Auto (Hi/Lo)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R410A / 1,850
Refrigerant control Capillary tube
Operation sound Indoor: Hi/Me/Lo/Qt* dB-A 45 / 41 / 37 / 32 44 / 40 / 36 / 32
(*Qt=Quiet mode at Lo) Outdoor: Hi dB-A 57 58
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 10
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 15.88(5/8)
Refrigerant tube kit / Accessories Optional / Air Clean Filter
Dimensions & Weight
Indoor Unit
Outdoor Unit
Unit dimensions Height mm 298 670
Width mm 1,065 880
Depth mm 218 285
Package dimensions Height mm 299 740
Width mm 1,140 1,022
Depth mm 379 400
Weight Net kg 12.0 56.0
Shipping kg 15.0 60.0
Shipping volume
m
3
0.129 0.303
DATA SUBJECT TO CHANGE WITHOUT NOTICE.