Control PCB
Control Circuit Fuse
Controls
Part No.
Microprocessor
250V 20A
W819A111
Outdoor Unit SAP-CRV12AEH
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
CC
External Finish
FVC50K ... 375
Aluminum Plate Fin / Copper Tube
2
1.4
Face Area
m
2
0.357
Coil
Rows
Fin Pitch mm
Heat Exchanger Coil
Compressor Oil ... Amount
Type
Compressor Model / Nominal Output
Compressor
Coil Resistance (Ambient Temp. 20 °C)
Ohm
DC Rotary (Inverter)
1YC23AEXD / 900W
1.764
CT (Peak current cut-off control)
Compressor Discharge Temp. Control
Overload Relay
Safety Device
Model
Operation Temp.
Micro F
VAC
Run Capacitor
Crankcase Heater
Yes
Yes
-
-
-
1 ... D370
Fan
Propeller
Q'ty ... Dia. mm
Type
Micro F
VAC
2
450
FW30N ... 1
6
30
930 / 930
Ohm
AC Motor
(Ambient Temp. 20 °C)
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool / Heat)
Run Capacitor
Type
Model ... Q'ty
No. of Poles
W
Open 120 °C
CS-7SA
Acrylic baked-on enamel finish
Main : 288.7
Aux : 188.3
95
135
Thermal protector
Open °C
°C
Operating Temp.
Type
Close
Safety Device
12

Table of Contents

Other manuals for Sanyo SAP-KRV12AEH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sanyo SAP-KRV12AEH and is the answer not in the manual?

Sanyo SAP-KRV12AEH Specifications

General IconGeneral
BrandSanyo
ModelSAP-KRV12AEH
CategoryAir Conditioner
LanguageEnglish

Related product manuals