(1) Indoor Temperature Sensor
Detect malfunctions of temperature sensor any time.
(2) Indoor Pipe Temperature Sensor
In defrosting period, the temperature sensor malfunction will not be detected.
5 minutes after finishing defrosting, the system begins to detect the temperature sensor malfunction.
In other times, the temperature sensor malfunction will be detected.
(3) Protection of Temperature Sensor
(3-1) When short-circuit occurs to the temperature sensor for 30 seconds
 The temperature sensor overheats. In this case, the complete unit will stop for protection.
 At the same time, the temperature protection and temperature sensor malfunction will be shown.
(3-2) When break-circuit occurs to the temperature sensor for 30 seconds
 The unit will stop and the temperature sensor malfunction will be displayed.
7-2-10. Temperature Sensor Malfunction Detection
33