EasyManua.ls Logo

SATO WS412TT - ESC+W1 IP Address

SATO WS412TT
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
198
System
Available for
WS4 series
ESC+W1 IP Address
ESC+W1
Hex code
ESC
W1
Parameter
<1B>16
<57>16<31>16
a~a
Default setting
a~a=000000000000
Persistence of the
command
When printer is powered off
Set Parameter will be retained
Validity in a job
Becomes invalid after execution
Validity after a job
Becomes invalid after the job
[Function]
Sets IP address.
[Format]
<W1>a~a
●Parameter
a~a [IP address] = 12 digit fixed
[Coding Example]
<A>
<W1>123220000040
<Z>
[Notes]
1. Place this command between start code<A> and stop code<Z>.
2. This command may not be used in combination with other commands.
3. Setting can be printed on the factory test print.
4. The set parameter will become valid after rebooting.
5. Default setting of IP address is as follows:
IP address
000000000000
IP Address

Table of Contents