33
Adjustment of the convection air in the high top Middle position:
Vent closed
Side position:
Vent open
SETTINGS
FOR NORMAL LOAD:
Primary air: 0 - 30%
Secondary air: 50 - 70%
baffle plate
CB-technique
Primary air
Secondary air
Ash drawer Handle for riddling grate
100%
0%
Adjustment of air supply
HANDLE FOR RIDDLING GRATE
The stove is equipped with a riddling grate that - when activated - empties the ashes from the burn chamber into the ash tray.
¬ The riddling grate must be half open during the firing.
REFUELING ON TO A LOW FIRE BED
If there is insufficient burning material in the fire bed to light a new fuel charge, excessive smoke emission can occur. Refueling
must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable
period. If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke.
OPERATION WITH DOOR LEFT OPEN
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left open
except as directed in the instructions.
DAMPERS LEFT OPEN
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not be operated with air
controls, appliance dampers or door left open except as directed in the instructions.