#SC 40RT 06 101027 Page 11 of 44
Flow versus pressure
The inlet pressure has been measured at the machine inlet. In order to achieve
the performance indicated in the curves, pressure drop in supply lines must be
taken into consideration.
6 7 8 9 10 11 12
0
5
10
15
20
25
30
35
40
45
50
55
2 x Ø6 mm
2 x Ø7 mm
2 x Ø8 mm
2 x Ø10 mm
2 x Ø12 mm
2 x Ø14 mm
2 x Ø16 mm
100 120 140 160
90 110 130 150 170
0
22
44
66
88
110
132
154
176
198
220
242
m
3
/h
USgpm
psi
bar