www.scheppach.com
24
|
GB
Important: The generator is equipped with an over-
load cut-out.
This shuts down the socket (7). You can reactivate the
socket (6) by pressing the overload cut-out (7).
Important! If this happens, reduce the electric
power you are taking from the generator or remove
any defective connected appliances.
10. Cleaning
Caution!
Switch o the motor and pull the spark plug boot from
the spark plug before doing any cleaning and mainte-
nance work on the equipment.
We recommend that you clean the equipment immedi-
ately after you use it.
Machine
• Keep all safety devices, air vents and the motor
housing free of dirt and dust as far as possible. Wipe
the equipment with a clean cloth or blow it with com-
pressed air at low pressure.
• We recommend that you clean the device immedi-
ately each time you have nished using it.
• Clean the equipment regularly with a moist cloth
and some soft soap. Do not use cleaning agents or
solvents; these could attack the plastic parts of the
equipment. Ensure that no water can seep into the
device.
Air lter (g.6)
• The air lter should be cleaned after every 30 hours
of operation.
• Remove the air lter cover (8).
• Remove the lter element (7a).
• Clean the lter element with soapy water, rinse with
clear water and leave to dry well before reinstalling.
• Assemble in reverse order
Spark plug (g.8 + 9)
Check the spark plug for dirt and grime after 10 hours
of operation and if necessary clean with a copper wire
brush. Thereafter service the spark plug after every 50
hours of operation.
• Remove the spark plug cap (8a).
• Clean any dirt from around the spark plug base.
• Use the wrench to remove the spark plug.
Mixture 2- stroke - oil
Regular unleaded
Petrol
1:40
0,025 l 1l
0,05 l 2l
0,075 l 3l
0,1 l 4l
9. Initial operation
Starting the engine
• Before starting , ensure that no applicance has been
connected to the generator .
• Open the petrol cock (5a) by turning it down
• Move the ON/OFF switch (5) to position “I” with the
key.
• Move the choke lever (3) to position “START”.
• Start the engine with the reversing starter (4) by pull-
ing the handle forcefully. Return the reversing starter
gently and slowly to the original position by hand. If
the engine does not start, pull the handle again.
• Note: when the motor is started for the very rst
time. It will require a number of attempts to start until
the fuel has travelled from the tank to the motor.
• Push the choke lever (3) back again after the engine
has started. (RUN)
Important: This socket may be loaded continuously
(S1) with 650W and temporarily (S2) for a maximum of
2 minutes with 700W.
• The generator is suitable for 230 V~ a.c. appliances.
• Do not connect the generator to the household net-
work as this may result in damage to the generator
itself or to other electrical appliances in your home.
Note: Some electrical appliances (power jigsaws,
drills, etc.) may have a higher level of power consump-
tion when used in dicult conditions.
Switching o the engine
• Before you switch o the generator, allow it to run
briey with no consumers so that it can “cool down”
• Move the ON/OFF switch (5) to position “O” with the
key.
• Close the petrol cock