Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the
devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Inclusion
One-button Add lock to Z-Wave Network (Inclusion) 1.Place your home automation system or panel into the Add or Inclusion Mode (Refer to the respective
documentation for that specific home automation system or panel device for details). 2.Remove the battery cover of the deadbolt. 3.Press then release the button
on the PCB.4.An LED will flash amber indicating the Add or Inclusion process is in progress. If the Security Scheme is Security 2 (S2), verify the DSK of the lock at
the Z-Wave Controller. The PIN Code portion of the Z-Wave DSK will be needed.5.When a green LED turns ON, the Add or Inclusion has completed successfully.
6.If a red LED turns ON, try repeating steps 1-3Interactive Instruction for Addhttps://instructions.allegion.com/instr/86/2543
Exclusion
One-button Remove lock from Z-Wave Network (Exclusion) 1.Place your home automation system or panel into the Remove or Exclusion Mode (Refer to the
respective documentation for that specific home automation system or panel device for details). 2.Remove the battery cover of the deadbolt. 3.Press then release
the button on the PCB. 4.An LED will flash amber indicating the Remove or Exclusion process is in progress. 5.When a green LED flashes 3 times, the Remove or
Exclusion process is completed successfully. 6.If a red LED turns ON, try repeating steps 1-3 Interactive Instruction for
Removehttps://instructions.allegion.com/instr/86/2581
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
1. Make sure a device is in factory reset state before including. In doubt exclude before include.
2. If inclusion still fails, check if both devices use the same frequency.
3. Remove all dead devices from associations. Otherwise you will see severe delays.
4. Never use sleeping battery devices without a central controller.
5. Dont poll FLIRS devices.
6. Make sure to have enough mains powered device to benefit from the meshing
Association - one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are
always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a 'Basic Set' Command.
Association Groups:
Group Number Maximum Nodes Description
1 2 Z-Wave Lifeline
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further
enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the
desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 10: Lock Specific Alarm Kick Sensitivity
This configuration setting indicates the sensitivity setting of the Forced Entry function of the built-in alarm.
Size: 1 Byte, Default Value: 3
Setting Description
1 - 5 Alarm Forced Entry Sensitivity
Parameter 11: Lock Specific Alarm Disable Local Controls
This configuration setting controls the ability to ENABLE or DISABLE local control of the built-in alarm function.
Size: 1 Byte, Default Value: -1
Setting Description
0 Alarm Disable Local Controls
-1 Alarm Enable Local Controls
Parameter 12: Get Electronic Transition Count
This configuration setting indicates the number of transitions from locked to unlocked or unlocked to locked state via electronic activation.
Size: 4 Byte, Default Value: 0