Description shortcut icons
How to lock from Inside
(Auto locking / Manual locking)
When the door is closed, it will be locked
automatically.
If the door is not opened within 7 seconds
after input secret code, it will be relocked
automatically to protect user`s property.
1. Auto locking function 2. Auto relocking system
How to lock from inside
1. In Auto locking mode
When the door is closed, door is locked
with beep sound with voice guide
automatically.
2. In Manual locking mode
After closing door, press [open/close] button,
then door is locked with beep sound with
voice guide.
Before closing the door, make sure that deadbolt is not extrude.
Note
The lamp
flashes when
the door is
locked.
♪BikBik~Biririk
The lamp
flashes when
the door is
locked.
♪~Biririk
˙ Please con󽗉rm that the door is properly closed.
(Setting of double Locking mode is available when the door is closed.)
˙ With pulling down handle from Inside,double locking mode shall be released automatically.
˙ If the sound is set to mute, there is no status sound. only indicating lamp is 󽗊ickering.
Note
How to set double locking function
or
Double locking
Cancel
1.
Double lock button
move right side
2. Pulling down this
handle
Double locking
Set up
1.
Double lock button
move left side
1. [Double locking] Set up 2. [Double locking] Cancel
How to replace battery
If battery lamp in RED is 󽗊ickering with sound, separate battery cover, and replace all 4 battery
to new one, 6V(1.5V "AA" size LR6 Alkaline)
How to apply external power in the emergency
PIN code
C
Card / Fob
How to unlock / lock from outdoor
How to unlock from outdoor
PIN code
C
Card / Fob
Fingerprint
How to unlock from outdoor (Mute function)
PIN code
OFF
C
Card / Fob
OFF
How to lock [Auto lock / Manual lock] from out door
Auto lock
※ If the door is not closed correctly, warning sound can be
caused. Please check and con󽗉rm the door closing status.
Manual lock
0
How to set auto locking / manual locking
Auto lock
In Auto locking mode, door will be locked automatically after
closing.
In Manual locking mode, door will be locked with pressing manual
lock button after closing.
* Please do the change/registration of new code at door opened
status to prevent unintentional locking.
Manual lock
How to use random security coding function
Usage
RAN
DOM
CODE
C
To register / to delete remote key (Communication pack)
Only for
S-6500FYSB
REG.
Remote
key
1
C
or
#
or
DEL.
All
remote key
2
C
or
#
Only for
S-6500FYSV
REG.
Remote
key
1 4
C
or
#
or
DEL.
All
remote key
2 4
C
or
#
How to lock / unlock by remote key
Unlock Lock
How to register / delete BLE pack (Only for S-6500FYSB)
REG.
1
C
or
#
Proceed according to the APP
explanation.
DEL.
2
C
or
#
How to register / delete Z-WAVE pack (Only for S-6500FYSV)
REG.
1 6
C
or
#
Proceed according to the
Z-Wave Plug-in manual.
DEL.
2 6
C
or
#
Repeat Highlighted part for continuous register or delete.
Rev.03
Additional function
How to control voice guide volume
Min. volume
#
C
or
#
1
1
Mid. volume
2
Max. volume
3
Guest PIN code (Temporary use)
REG.
#
C
or
#
2 RC
#
RC
#
How to control operation volume
Vol. up
#
C
or
#
3
9
Vol. down
7
Status checking guide
Voice guide
#
C
or
#
4
Check battery capacity
Checking the
battery
#
C
or
#
5
Warning function against Illegal entry or hacking
Operate
Wrong PIN code three times/unregistered card three times/
unregistered 󽗉ngerprint 󽗉ve times
Warning alarm function against forced entry
PIN code
C
Card / Fob
Normal mode : ideal for new users or low security environments
Safety mode : higher security level via use of a manager PIN code. Provides individual register and delete
function
: [N] button : [S] button : Card / Fob : Fingerprint
UC
: User code
MC
: Manager code
RC
:
Registration
c
ode
How to change from normal mode to safety mode
1 2 3 4 5 6 7 8 9 10 11
Safety mode
3"Sec
UC
#
MC
#
MC
#
How to change from safety mode to normal mode
Normal mode
3"Sec
MC
#
UC
#
UC
#
How to change Normal mode / Safety mode
Normal mode
1 2 3 4 5 6 7 8 9 10
REG.
PIN code
1 4
RC
ㆍㆍㆍ
Card / Fob
1 5
ㆍㆍㆍ
Fingerprint
1 6
DEL.
All
Card / Fob
2 5
All
Fingerprint
2 6
Repeat highlighted part of diagram above for continuous register or delete
Safety mode
Warning : Please do not forget manager code.
If you forget this number should contact to your local agency.
: [N] button : [S] button : Card / Fob : Fingerprint
UC
: User code
MC
: Manager code
RC
:
Registration Code
Safety mode
1 2 3 4 5 6 7 8 9 10 11 12
REG.
PIN code
1 4
MC
or
#
RC
Card / Fob
1 5
MC
or
#
Card
Registration
Number(2digits)
#
Finger
print
1 6
MC
or
#
Finger print
Registration
Number(2 digits)
3 times
#
DEL.
All
Card / Fob
2 5
MC
or
#
Individual
Card / Fob
3 5
MC
or
#
Card
Registration
Number(2digits)
#
All
Fingerprint
2 6
MC
or
#
Individual
Fingerprint
3 6
MC
or
#
Finger print
Registration
Number(2 digits)
#
Safety mode (Manager)
Change
Manager
code
8 4
MC
or
#
RC
#
RC
#
REG.
Manager
Card / Fob
8 5
MC
or
# #
DEL.
All manager
Card / Fob
8 6
MC
or
#
5
Repeat highlighted part for continuous register or delete
Each product has a different access pack, so please check your product
before purchasing it.
NOTICE
Only for S-6500FYSB
Only for S-6500FYSV
ㆍPIN code: 10 entries (6-12 digits) / Card / Fob: 50 entries / Fingerprint : 100 entries
ㆍPIN code: 10 entries (4-10 digits) / Card / Fob: 50 entries / Fingerprint : 50 entries
Wireless communication device installation
1. Open the battery cover on the lock and remove the batteries.
2. Plug in the wireless communication device.
3. Insert the batteries back into the lock.
4. Audible melody will sound if successful.
˙ Please insert the device in the
correct position.
Note
How to register remote key & to unlock or lock
1.5v ‘AAA’ size
alkaline
battery 1 EA
Indication lamp
[Lock] button
[Unlock] button
ㆍRemote key : 5 entries
: [Communication function] button
: Remote unlock : Remote lock
C
: PIN code : Card / Fob
2. 󾘬 Access (Only for S-6500FYSV)
Please check 󾘥󾘬󾘥󾘬󾘥󾘥 provided with the
communication pack.
※ Required to use access packs by product. (Optional parts)
3. Using the󾘥󾘥 (Only for S-6500FYSB)
※ Communication packs(Mobile Access) must be purchased separately.
Communication pack / Remote key
(optional)
Connecting with the mobile app
Disconnecting the app from the door lock
1. Install the Schlage Base via the APP Store or Google Play.
2. Activate the app (new user must register account first) and press the
” icon at
the top of the screen and select a door lock from the list.
3. Connect the door lock by following the guide provided in the app.
󾘥󾘥󾘯󾘥
Press and hold the [ ] button for 3 seconds.
Then, press 1 on the keypad and enter the passcode followed by the [] button.
1. Press and hold the [
] button for 3 seconds.
2. Then, press 2 on the keypad and enter the passcode followed by the [] button.
: [N] button
C
: PIN code : Trespass alarm
:
[S] button
: Card / Fob : Unlock
: [ ] button
:
9V alkaline battery(6LF22) : Lock
#
: [#] button
UC
: User code
: Touch the front pad
MC
: Manager code
: [Communication
function] button
RC
: Registration code
RAN
DOM
CODE
: Random code
※ Normal mode : [N] button / Safety mode : [S] button
ㆍPIN code: 10 entries (6-12 digits) / Card / Fob: 50 entries / Fingerprint : 100 entries
ㆍPIN code: 10 entries (4-10 digits) / Card / Fob: 50 entries / Fingerprint : 50 entries
Only for S-6500FYSB
Only for S-6500FYSV
Normal mode