Assembly
08.00 | MPG-plus | Assembly and operating manual | en | 0389216
37
5.3.8.2 Mounting the FPS-S 13
Sizes MPG-plus 20 / 25 / 32
For these sizes, the sensor is mounted directly to the housing.
Ø Position the sensor (3) with the circular elevation (1) in the re-
cess at the housing (2).
Ø Fasten the sensor using the screws (4).
Tightening torque: 1 Ncm
Ø Connect the control unit output and adjust the sensor (see as-
sembly and operating manual of the sensor).
Sizes MPG-plus 40 / 50 / 64
For these sizes, a bracket must be mounted. This bracket is avail-
able at SCHUNK.
Ø Fasten the bracket (1) using the screws (2).
Ø Fasten the sensor (4) using the screws (3).
Tightening torque: 1 Ncm