Assembly
04.00 | SKE | Assembly- and Operating Manual | en | 389407
15
4.1.2 Pneumatic connection
WARNING
Risk of injury due to moving parts!
Rotating components and/or components moving linearly may
cause severe injuries.
Do not interfere with moving parts during operation.
Wear protective equipment.
NOTE
Observe the requirements for the compressed air supply,
Technical Data [
}
13].
In case of compressed air loss (cutting off the energy line), the
components lose their dynamic effects and do not remain in a
secure position. However, the use of a SDV-P pressure
maintenance valve is recommended in this case in order to
maintain the dynamic effect for some time. Product variants
are also offered with mechanical gripping force via springs,
which also ensure a minimum clamping force in the event of a
pressure drop.
NOTE
The air connections are equipped with one-way flow control
valves.
The optimal swiveling speed is achieved by adjusting the swiveling
time on the exhaust air throttles.
Fine adjustment must be carried out on the fully assembled
system. Never operate the swivel unit without the one-way flow
control valves mounted. Do not go below the specified swiveling
time.
CAUTION
Material damage due to too high swiveling speed!
If the swiveling speed is too high, the assembly will be
decelerated abruptly by the shock absorber and will continue to
oscillate until reaching the end position. This will overload the
shock absorber and may cause damage to it.
Adjust the swiveling speed in a way, that the movement
decelerate smoothly in the end position.