48QB218 6.1.2019 vers 1.0
SET POINT
Displays the factory default Set Point temperature for each machine type. See Temp secon for the
specic machine refrigeraon modes. Ambient snack machines without a refrigeraon system
will display 43 °F.
These temperatures may be adjusted, however it is not advised without direcon by an authorized
technician. The opmal temperatures have been set according to NAMA specicaons for opmal
product safety. Before making any adjustment see Temp and Health Safety secon.
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2. Press 5 for Opons Menu Opons
3. Press 8 for Set Point
Setpoint (Current Seng)F
*-Exit 8-Edit
4. Press 8 to edit the temperature Set Point
Setpoint (Choice Flashing)F
*-Exit #-Save
5.
Connue pressing 8 unl the desired tem-
perature is shown on the display
Setpoint (New Temp)F
*-Exit 8-Edit
6. Press # to save the seng
Setpoint (New Seng)F
*-Exit 8-Edit
7. Press * three mes to exit 0.00
SENSITIVITY ADJUST
The drop sensor sensivity is factory set as follows:
Selecons 140-144 Medium; Selecons 145 and 146 High; Selecon 147 Low
These sengs should not be changed unless advised by technical support sta. Please see the
Troubleshoong secon for instances that require adjustment under advisement.
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2. Press 5 for Opons Menu Opons
3. Press 9 for Sensivity Adjust
Sensivity Adjust
*-Exit 3-Edit by Selecon
4.
Press 3 to adjust the sensivity on the drop
sensors by selecon (numbers 1 and 2 are n/a
in this machine)
Selecon: ___
*-Exit #-Save
5.
Press the selecon number you wish to
change. NOTE: Only beverage selecons
have a drop sensor to adjust (selecons 140
through 147). Press 1 to edit the sensivity to
High, Medium or Low.
Selecon: 145 HIGH
*-Exit 1-Edit
6. Press # to Save your changes.
Selecon: 145 (new seng)
*-Exit 1-Edit
7. Press * three mes to exit 0.00