48QB218 6.1.2019 vers 1.0
SET POINT
Displays the factory default Set Point temperature for each machine type. See Temp secon for the
specic machine refrigeraon modes. Ambient snack machines without a refrigeraon system
will display 43 °F.
These temperatures may be adjusted, however it is not advised without direcon by an authorized
technician. The opmal temperatures have been set according to NAMA specicaons for opmal
product safety. Before making any adjustment see Temp and Health Safety secon.
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2. Press 5 for Opons Menu Opons
3. Press 8 for Set Point
Setpoint (Current Seng)F
*-Exit 8-Edit
4. Press 8 to edit the temperature Set Point
Setpoint (Choice Flashing)F
*-Exit #-Save
5.
Connue pressing 8 unl the desired tem-
perature is shown on the display
Setpoint (New Temp)F
*-Exit 8-Edit
6. Press # to save the seng
Setpoint (New Seng)F
*-Exit 8-Edit
7. Press * three mes to exit 0.00
SENSITIVITY ADJUST
The drop sensor sensivity is factory set as follows:
Selecons 140-144 Medium; Selecons 145 and 146 High; Selecon 147 Low
These sengs should not be changed unless advised by technical support sta. Please see the
Troubleshoong secon for instances that require adjustment under advisement.
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2. Press 5 for Opons Menu Opons
3. Press 9 for Sensivity Adjust
Sensivity Adjust
*-Exit 3-Edit by Selecon
4.
Press 3 to adjust the sensivity on the drop
sensors by selecon (numbers 1 and 2 are n/a
in this machine)
Selecon: ___
*-Exit #-Save
5.
Press the selecon number you wish to
change. NOTE: Only beverage selecons
have a drop sensor to adjust (selecons 140
through 147). Press 1 to edit the sensivity to
High, Medium or Low.
Selecon: 145 HIGH
*-Exit 1-Edit
6. Press # to Save your changes.
Selecon: 145 (new seng)
*-Exit 1-Edit
7. Press * three mes to exit 0.00