59QB218 6.1.2019 vers 1.0
24.
Press * two mes to return to Shutdown
menu
Shutdown
25. Press 2, 3 or 4 to edit Intervals 2, 3 or 4 IntervalX
26.
Press 9 for Enable menu (Enable must be on
to start shut down)
Enable (Current Seng)
*-Exit 9-Edit
27. Press # to save the seng
Lighng (New Seng)
*-Exit 8-Edit
28. Press * ve mes to exit to Sales Mode 0.00
ENERGY SAVINGS
Use this menu to set a non-health safety machine to run at a higher than normal temperature during
set mes. This will save energy during o peak hours of sales. Two intervals are available.
STEP DISPLAY
1. Press Service Mode Buon Motor Count or Error Code **
2.
Press 6 for Password (Advanced Features)
Menu
Password
3. Enter Password (default 2314) Advanced Features
4. Press 6 for Energy Savings Energy Savings
5.
Press 1 for Interval1 (2 for Interval2, and so
on)
Interval1
6. Press 4 for Day menu Day
7. Press 1 for All Days
All Days (Current Seng
*-Exit 1-Edit
8. Press 1 to toggle All Days ON/OFF
All Days (New Seng)
*-Exit #-Save
9. Press # to save the seng
All Days (New Seng)
*-Exit 1-Edit
10. Press 2 to toggle Monday ON/OFF
Mon (Choice Flashing)
*-Exit 2-Edit
11. Press # to save the seng
Mon (New Seng)
*-Exit 2-Edit
Use numbers 3-8 to complete the other days of the week using steps 10 and 11.
12.
Press * two mes to return to Interval1
menu
Interval1
13. Press 5 two mes for Start Time menu
(Current Time)
*-Exit 5-Edit
14.
Press 5, then enter Start Time in 24-hr me
(HH:MM)
New Time
*-Exit #-Save
15. Press # to save the me
New Time
*-Exit 5-Edit
16.
Press * two mes to return to Energy Savings
menu
Energy Savings