13
Settings
Measurements
Name Default Max value Min value Step Unit
Thermostat type Auto Electronic
Cut out temperature
fridge
10 40 -40 1 Celsius (°C)
Difference fridge 2 15 1 1 Kelvin (K)
Cut out temperature
freezer
-4 40 -40 1 Kelvin (K)
Difference freezer 2 | 2 15 1 Celsius (°C)
Operating state Fridge Kelvin (K)
Name Description Step Unit
Runtime
Runtime is provided to record the cooling-time
(thermostat cut-in period). The runtime is updated
during cooling, starting with 0 at start of cooling.
During cooling OFF (Thermostat cut-out), the Runtime
will show the time from the previous cooling period.
Runtime is reset at cooling ON period. At power-up
the reading is reset.
1 Minutes
Actual temperature
Actual air temperature when a NTC 1 sensor is used.
At mechanical thermostat, an ON or OFF status is
shown
Celsius (°C)
Actual cut in
temperature fridge
Cut out temperature fridge+ Difference fridge Celsius (°C)
Actual cut in
temperature freezer
Cut out temperature freezer+ Difference freezer Celsius (°C)
Auxiliary temperature Temperature measured by second NTC 2 Celsius (°C)