Electrical Hardware
Key-Parameters
Below you can find a list with the key parameters for the electronic unit 101N01010
3.
ELECTRICAL HARDWARE
KEY-PARAMETERS
Name Reference /value / Standards
Type code 101N01010
Humidity test passed according to Static humidity according to IEC 60068-2-3
Damp heat According to EN60068-2-30 test Db
Maximum Operating temperature 55 °C (70 °C for running communication)
Minimum Operating temperature -25 °C (-40 °C for running communication)
Storage temperature - 40 °C to 90 °C
EMC approval/ conformity According to 2004/104/EC
External fuse required Max. 10 A Slow blow
Leakage current 50 µA (When wake up signal is OFF)
Condenser Fan output 5 W, nominal voltage 12 V max limited to 14 V
NTC type to be connected Epcos M800/5K
Input voltage 8.5 – 17 V DC (Nominal voltage 13,8 VDC)
Starting Current 8 A
Current consumption under running conditions See section 21
LED output Max. 15 mA