General
Application
Cooling requirements
Motor
Design
21.
TECHNICAL DATA BD1.4F-AUTO
COMPRESSOR
Code number (without electronic unit) 109Z0102
Electronic unit 12 V single: 101N1010
Compressors on pallet 180
Application LBP/MBP
Evaporating temperature °C -25 to 5
Voltage range 9-17 V DC
Max. condensing temperature continuous (short) °C 60 (70)
Max. winding temperature continuous (short) °C 125 (135)
Application LBP MBP HBP
32°C S S
38°C S S
43°C S S
Remarks on application:
Motor type permanet magnet, brushless DC
Resistance, all 3 windings (25°C) mΩ 50
Displacement cm
3
1.41
Oil quantity (type) cm
3
75 (polyolester)
Maximum refrigerant charge g 150
Free gas volume in compressor cm
3
500
Weight - compressor/electronic unit kg 2.1/0.17