7
6.
POWER CONSUMPTION MONITORING
Power Consumption
Monitoring
Compressor power consumption is monitored at 10 minute intervals. The following information is viewed
using the TOOL4COOL® interface:
Compressor power consumption
Cumulative power consumption since start up
Cumulative power consumption of the previous period
The user can reset power consumption to zero using the reset power consumption function
Name Description Step Unit
Power consumption Actual Power consumption 1 W
Power consumption
since start-up
Power consumption since start of power supply 1 Wh
Power consumption
last period
Power consumption from the
previous power cycle (the consumption in the time
where the main switch or the DI input as been ON)
1 Wh