TO SET - ELAPSED DIVE TIME ALARM
(while in the Surface Mode)
Factory set for 0:00 hr:min, the Alarm can be set to
values between 0:10 and 3:00 hr:min in increments of
0:05 hr:min.
• Press Both buttons simultaneously, release when
SET: 1 appears.
• Press and release the Advance (Front) button, FO2
appears with the value flashing.
• Press the Advance (Front) button 2 more times.
• The graphic EdT, and Alarm and Dive Time icons
appear with the Elapsed Dive Time value flashing
(Fig. 23).
• Press and release the Select (Side) button until the
desired Alarm value appears, then release the button.
• Press the Advance (Front) button to accept the
setting and advance to PC Interface, or press and hold
Both buttons for 2 seconds to revert to Surface Mode.
Fig. 23 - Set Elapsed Time Alarm