EasyManuals Logo

Sega Initial D4 User Manual

Sega Initial D4
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
74
TROUBLESHOOTING
16
Error 11
DISPLAY JVS I/O board is not connected to main board.
CAUSE (1) The I/O board is not connected.
(2) Unreliable connection between the main board and the I/O board.
COUNTERMEASURES (1) Connect the I/O board to the main board. Verify that the power cable is
connected to I/O board.
(2) Reconnect or replace the JVS cable that connects the I/O board to the
main board.
Error 12
DISPLAY JVS I/O board does not ful ll the game spec.
CAUSE The correct I/O board is not connected.
COUNTERMEASURES Use an I/O board that provides the proper input/output for the game.
Error 14
DISPLAY Network rmware version does not ful ll the game spec.
Required version XX.XX.
CAUSE The rmware version installed on either the network board or the DIMM
Media board is older than the required version.
COUNTERMEASURES Use a network board or DIMM Media board with rmware that meets or
exceeds the required version.
Error 15
DISPLAY Game Program Not Found.
CAUSE The key chip is not connected.
COUNTERMEASURES Check that the key chip is connected correctly. Check that the key chip is
not inserted the wrong way or that the key chip from a different system is not
inserted.
Error 21
DISPLAY Game Program Not Found on Game Disk.
CAUSE There is no program image on the game disk.
COUNTERMEASURES Check that a game disk corresponding to the key chip is inserted into the
drive.
Error 22
DISPLAY Game Program Not Found on Device.
CAUSE There is no game image on the game installer device.
COUNTERMEASURES Perform a reinstall from the game disk.
Error 24
DISPLAY DVD Drive Not Found.
CAUSE The DVD drive cannot be found.
COUNTERMEASURES Connect the DVD drive.
Error 25
DISPLAY Game Disk Not Found.
CAUSE The game disk cannot be found.
COUNTERMEASURES Insert the game disk.
Error 26
DISPLAY Storage Device Not Found.
CAUSE The program installer device cannot be found.
COUNTERMEASURES Send the LINDBERGH board in for repair with the key chip still in place.
Error 27
DISPLAY Storage Device is Not Acceptable.
CAUSE The program installer device does not have enough space.
COUNTERMEASURES Send the LINDBERGH board in for repair with the key chip still in place.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sega Initial D4 and is the answer not in the manual?

Sega Initial D4 Specifications

General IconGeneral
BrandSega
ModelInitial D4
CategoryGame Console
LanguageEnglish

Related product manuals