Do you have a question about the Seko KRONOS 20 pH/ORP and is the answer not in the manual?
Type | pH/ORP Controller |
---|---|
Output | 4-20 mA, Relay |
Measurement Range pH | 0-14 pH |
Resolution pH | 0.01 pH |
Resolution ORP | 1 mV |
Accuracy pH | ±0.01 pH |
Accuracy ORP | ±1 mV |
Protection Rating | IP65 |
Input | pH/ORP Electrode |
Measurement Range ORP | -1000 to +1000 mV |
Temperature Compensation | Automatic, 0-100°C |
Operating Temperature | 0-50°C |
Storage Temperature | -20 to 60°C |
Explains the function of the 'enter prog' and 'ESC' buttons on the control panel.
Details the electrical connections and the wiring diagrams for probes and power supply.
Details the procedure to enter the programming mode using specific button presses.
Explains navigating menu items, editing values, and saving or discarding changes.
Allows selection of the user interface language from available options.
Explains the pump's operation in constant mode, including Time ON and Time OFF settings.
Details the display elements showing function mode, alarms, pump status, and dosing values.
Configures proportional dosing parameters for pH measurement, including set-point and bands.
Configures Over Feed Alarm time and manual temperature unit selection (°C or °F).
Details the display elements showing pH value, alarms, pump status, and dosing values.
Configures proportional dosing parameters for Redox measurement, including set-point and bands.
Configures Over Feed Alarm time and activation of calibration procedure.
Details the display elements showing Redox value, alarms, pump status, and dosing values.
Sets a delay for pump operation at start-up, adjustable from 1 to 60 minutes.
Sets a delay after probe calibration before pump operation resumes, adjustable from 1 to 60 minutes.
Guides through calibrating the flow rate by measuring dispensed volume and updating system memory.
Shows pump operating time, tube replacement time, quantity dosed, and alarm counts.
Sets or removes a password to restrict access to programming and setup parameters.
Allows activation/deactivation of the flow sensor and selection of its N. Open/N. Closed state.
Configures the level sensor alarm to stop dosage or just signal an event.
Configures the pause input to be Normally Open or Normally Closed for remote pump pausing.
Details the automatic pH calibration process, including buffer solution steps and quality checks.
Details the manual pH calibration process, including buffer solution steps and value entry.
Details the automatic Redox calibration process, including buffer solution steps and quality checks.
Details the manual Redox calibration process, including buffer solution steps and value entry.
Explains the process to prime the pump to ensure proper operation and fluid transfer.
Details the steps for replacing the pump tubing, including required intervals or conditions.
Provides a guide to identify alarm conditions, their causes, and the necessary corrective actions.