Accessories
Lumisphere Use the Lumisphere when you wish to measure incident light for
portraits and three-dimensional subjects. In case of incident light
measurement, point the Lumi-sphere accurately toward the camera
from the subject position.
Lumidisc •Use the Lumidisc to measure illumination contrast or Lux as well as
exposure of single-dimensional subjects. Measuring position is same
as for Lumisphere.
Reflected Light Filter •Use the reflected light filter to measure the reflectedlight of a
subject. Point the filter directly toward the part of subject to be
measured. And measure the reflected light from the main part of
subject as close as possible to the subject. Use adequate care in
this case that the meter shadow does not interfere with the light to
be measured.
Synchro Cord (sold A necessity for wired measurement for flash light.
separately) 5 meters in length, with 3 plugs for the synchro termials of exposure
meter, flash unit and camera.
Viewfinder (sold By using this viewfinder the spot measurement is
separately) available. It makes you possible to measure the reflected light of
distant subject without going up close to the subject, or to check the
reflected light from the small part of subject.