Schweitzer Engineering Laboratories, Inc. SEL-487E Data Sheet
25
➤
Ethernet card options
➢ Four-port Ethernet card with port combinations
of:
➣ Four copper (10BASE-T/100BASE-TX)
➣ Four fiber (100BASE-FX)
➣ Two copper (10BASE-T/100BASE-TX) and
two fiber (100BASE-FX)
➢ Five-port Ethernet card with small form-factor
pluggable (SFP) ports (100BASE-FX and
1000BASE-X)
e
➤ Communications protocols
➢ Complete group of SEL protocols (SEL ASCII,
SEL Compressed ASCII, SEL Settings File
Transfer, SEL Fast Meter, SEL Fast Operate,
SEL Fast SER, resistance temperature detectors
(RTDs), Enhanced M
IRRORED BITS
Communications), DNP3, and Synchrophasors
(SEL Fast Message and IEEE C37.118 format)
➢ Above protocols plus IEC 61850 Edition 2
Contact the SEL factory or your local Technical Service
Center for particular part number and ordering informa-
tion (see Technical Support on page 34). You can also
view the latest part number and ordering information on
the SEL website at selinc.com.
Specifications
e
All ports support 100 Mbps speeds. PORT 5A and PORT 5B also sup-
port 1 Gbps speeds.
Note: You can order SEL-487E-5 as an SV subscriber relay or as a TiDL relay.
For SV applications, operating times are delayed by the configured channel
delay, CH_DLY. See <CrossRefBook>SV Network Delays on page 17.25 in
the SEL-400 Series Relays Instruction Manual for more details. For TiDL
applications, the operating times are delayed by a fixed 1 ms. Use caution
when setting relay coordination to account for this added delay.
Note: The metering and protection element accuracies specified for the
SEL-487E-5 SV Subscriber Relay are valid only when using SEL merging
units. For SV applications, third-party SV publisher devices are supported,
but hardware accuracies and analog filtering need to be considered to
determine the effect on SEL-487E-5 SV Subscriber performance.
Compliance
Designed and manufactured under an ISO 9001 certified quality
management system
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for
a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference in which case the
user will be required to correct the interference at his own expense.
UL Listed to U.S. and Canadian safety standards
(File E212775; NRGU, NRGU7)
CE Mark
RCM Mark
General
Frequency and Rotation
System Frequency: 50/60 Hz
Phase Rotation: ABC or ACB
Nominal Frequency Rating: 50 ±5 Hz
60 ±5 Hz
Frequency Tracking
(Requires PTs):
Tracks between 40.0–65.0 Hz
Below 40 Hz = 40 Hz
Above 65.0 Hz = 65 Hz
Default Slew Rate: 15 Hz per s
Power Supply
24—48 Vdc
Rated Voltage: 24–48 Vdc
Operational Voltage Range: 18–60 Vdc
Vdc Input Ripple: 15% per IEC 60255-26:2013
Interruption: 20 ms at 24 Vdc, 100 ms at 48 Vdc
per IEC 60255-26:2013
Burden
SV Relay: <35 W
TiDL Relay: <40 W
48—125 Vdc or 110—120 Vac
Rated Voltage: 48–125 Vdc, 110–120 Vac
Operational Voltage Range: 38–140 Vdc
85–140 Vac
Rated Frequency: 50/60 Hz
Operational Frequency
Range: 30–120 Hz
Vdc Input Ripple: 15% per IEC 60255-26:2013
Interruption: 14 ms @ 48 Vdc, 160 ms @ 125 Vdc
per IEC 60255-26:2013
Burden
SV Relay: <35 W, <90 VA
TiDL Relay: <40 W, <90 VA
125—250 Vdc or 110—240 Vac
Rated Voltage: 125–250 Vdc, 110–240 Vac
Operational Voltage Range: 85–300 Vdc
85–264 Vac
Rated Frequency: 50/60 Hz
Operational Frequency
Range: 30–120 Hz
Vdc Input Ripple: 15% per IEC 60255-26:2013
Interruption: 46 ms @ 125 Vdc, 250 ms @ 250 Vdc
per IEC 60255-26:2013
Burden
SV Relay: <35 W, <90 VA
TiDL Relay: <40 W, <90 VA
Control Outputs
Note: IEEE C37.90-2005 and IEC 60255-27:2013
Update Rate: 1/8 cycle
Make (Short Duration
Contact Current):
30 Adc
1,000 operations at 250 Vdc
2,000 operations at 125 Vdc