Specifications
53
In compliance with (mains unit)
The mains unit is certified in accordance with the legal safety requirements of Europe, the United
States, Canada, Russia and Japan.
Connector assignment
Mains unit*
* depending on country variant
NT 2–1 NT 2–3
Input voltage 110 V~ or 230 V~,
50/60 Hz
100 to 240 V~,
50/60 Hz
Power/Current consumption 9 VA max. 120 mA
Output voltage 13 V 12 V
Secondary output current 300 mA 400 mA
Energy efficiency level IV IV
Temperature range –10°C to +40°C –10°C to +40°C
Europe
EMC EN 55022, EN 55024,
EN 55014-1/-2
Safety EN 60065
USA
47 CFR 15 subpart B
Canada ICES 003
Audio Other connectors
¼” (6.3 mm) stereo
jack plug, balanced
XLR-3F connector,
balanced
¼” (6.3 mm) mono
jack plug, unbalanced
DC connector for
power supply
21