15
Dehumidification
Press the “Mode” button on the thermostat
and select the “Cool” position.
Press the down arrow and adjust the setting to 1° below
the current room temperature. The blower should come on
immediately on high speed, followed by cold air circulation.
The thermostat will indicate “Cooling” on the screen. Note
that there can be up to a 5 minute delay for this process.
This is indicated by a flashing setpoint temperature.
Press the “Menu” button on the thermostat and press
the “Next” button until you reach the “dH SP” screen.
Turn Dehumidification On by pressing either the Up or
Down button until the humidity setpoint is lower than
the current room humidity. Humidity can be adjusted
from 40% to 95% in 5% increments, then press “Exit.
Depending on installed equipment, check that the
system fan speed has slowed, the dehumidifier is
running, or the system cools up to 3° below temperature
set point or until the humidity set point is reached.
Press the up arrow and adjust the setting to 1° above
the current room temperature. The cooling system and
dehumidifier (if applicable) should both stop operating.